Page 13For technical questions, please call 1-888-866-5797.Item 37822 39797 39798
SAFETYOPERATIONMAINTENANCE SETUP
Troubleshooting
Problem Possible Causes Likely Solutions
Tool will not start. 1. Cord not connected.
2. No power at outlet.
3. Tool’s thermal reset breaker
tripped (if equipped).
4. Internal damage or wear. (Carbon
brushes or switch, for example.)
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is
unpowered, turn off tool and check
circuit breaker. If breaker is tripped,
make sure circuit is right capacity for
tool and circuit has no other loads.
3. Turn off tool and allow to cool.
Press reset button on tool.
4. Have technician service tool.
Tool operates
slowly.
Power being reduced by long or
small diameter extension cord.
Eliminate use of extension cord. If an
extension cord is needed, use one with the
proper diameter for its length and load. See
Extension Cords in GROUNDING section.
Performance
decreases
over time.
Carbon brushes worn or damaged. Have qualied technician replace brushes.
Excessive noise
or rattling.
Internal damage or wear. (Carbon
brushes or bearings, for example.)
Have technician service tool.
Overheating. 1. Forcing machine to work too fast.
2. Blocked motor housing vents.
3. Motor being strained by long or
small diameter extension cord.
1. Allow machine to work at its own rate.
2. Wear ANSI-approved safety goggles
and NIOSH-approved dust mask/
respirator while blowing dust out
of motor using compressed air.
3. Eliminate use of extension cord. If
an extension cord is needed, use
one with the proper diameter for
its length and load. See Extension
Cords in GROUNDING section.
Follow all safety precautions whenever diagnosing or servicing
the tool. Disconnect power supply before service.